Commit b3600f90 authored by Erik Asbjørn Mikkelsen Jensen's avatar Erik Asbjørn Mikkelsen Jensen
Browse files

added links to technical drawings

parent 2a30245e
......@@ -11,6 +11,9 @@
* Link to Microns own spec [sheets](/micron.pdf).
# W1
[Technical drawing](detector_spec/drawings/w1.pdf)
| ID | YEAR PURCHASED | SPEC SHEET | THICKNESS (um) | DEADLAYER F/B (um) | BIAS (V) | LEAKAGE (uA) | JSON FILE | PHYSICAL LOCATION | COMMENTS |
| :--- | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| AUW1_50_00 | - | - | 55 | -/- | - | - | [link](https://git.kern.phys.au.dk/ausa/ausalib/blob/master/res/Detectors/AUW1_50_00.json) | Aarhus | - |
......@@ -23,6 +26,10 @@
| AUW1_65_01 | 2017 | [link](/AUW1_65_01_specs.pdf) | 70 | -/- | - | - | - | Aarhus | Wafer no. 3187-1. Not tested yet |
# S3
[Technical drawing 1](detector_spec/drawings/s3.pdf)
[Technical drawing 2](detector_spec/drawings/s3_special.pdf)
| ID | YEAR PURCHASED | SPEC SHEET | THICKNESS (um) | DEADLAYER F/B (um) | BIAS (V) | LEAKAGE (uA) | JSON FILE | PHYSICAL LOCATION | COMMENTS |
| :--- | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| [AUS3_322_00](dets/AUS3_322_00) | 2005 | - | 320 | -/- | -200 | 1.000 | [link](https://git.kern.phys.au.dk/ausa/ausalib/blob/master/res/Detectors/AUS3_322_00.json) | Aarhus | ring 7 dead |
......@@ -31,11 +38,17 @@
| AUS3_60_00 | - | - | 64 | -/- | - | - | [link](https://git.kern.phys.au.dk/ausa/ausalib/blob/master/res/Detectors/AUS3_60_00.json) | Aarhus | - |
# BB7
[Technical drawing](detector_spec/drawings/bb7.pdf)
| ID | YEAR PURCHASED | SPEC SHEET | THICKNESS (um) | DEADLAYER F/B (um) | BIAS (V) | LEAKAGE (uA) | JSON FILE | PHYSICAL LOCATION | COMMENTS |
| :--- | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| [AUBB7_140_00](dets/AUS3_322_00) | 2017 | [link](/AUBB7_140_00.pdf) | 140 | -/- | -60 | 0.1 | [link](https://git.kern.phys.au.dk/ausa/ausalib/blob/master/res/Detectors/AUBB7_140_00.json) | Aarhus | - |
# Pads
[Technical drawing](detector_spec/drawings/msx25_special.pdf)
| ID | YEAR PURCHASED | SPEC SHEET | THICKNESS (um) | DEADLAYER F/B (um) | BIAS (V) | LEAKAGE (uA) | JSON FILE | PHYSICAL LOCATION | COMMENTS |
| :--- | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| AUPAD_1458_00 | - | - | 1458 | -/- | - | - | [link](https://git.kern.phys.au.dk/ausa/ausalib/blob/master/res/Detectors/AUPAD_1458_00.json) | Aarhus | - |
......@@ -47,3 +60,8 @@
The Clover detectors used at the Isolde Decay Station are of the so-called EUROBALL type.
Each detector consists of four HPGe crystals, and each crystal has a diameter of 50 mm and a length of 70 mm (see page 3 in [this document](/c39840_clover_detector_super_spec_3.pdf)).
# Others
[Technical drawing of regular MSX25](detector_spec/drawings/msx25.pdf)
[Technical drawing of different W design](detector_spec/drawings/w.pdf)
\ No newline at end of file